Open Registry Editor (regedit.exe) and configure the following registry entries:
HKLM\SYSTEM\CurrentControlSet\Services\W32Time\Parameters\Type
This registry entry determines which peers W32Time will accept synchronization from. Change this REG_SZ value from NT5DS to NTP so the PDC Emulator synchronizes from the list of reliable time servers specified in the NtpServer registry entry described below.
HKLM\SYSTEM\CurrentControlSet\Services\W32Time\Config\AnnounceFlags
This registry entry controls whether the local computer is marked as a reliable time server (which is only possible if the previous registry entry is set to NTP as described above). Change this REG_DWORD value from 10 to 5 here.
HKLM\SYSTEM\CurrentControlSet\Services\W32Time\Parameters\NtpServer
This registry entry specifies a space-delimited list of stratum 1 time servers from which the local computer can obtain reliable time stamps. The list may consist of one or more DNS names or IP addresses (if DNS names are used then you must append ,0x1 to the end of each DNS name). For example, to synchronize the PDC Emulator in your forest root domain with tock.usno.navy.mil, an open-access SNTP time server run by the United States Naval Observatory, change the value of the NtpServer registry entry from time.windows.com,0x1 to tock.usno.navy.mil,0x1 here. Alternatively, you can specify the IP address of this time server, which is 192.5.41.209 instead.
Now stop and restart the Windows Time service using the following commands:
net stop w32time
net start w32time
You should see some entries in the system event log stating that the box is receiving time from the server.